Product introduction
JATS series automatic transfer switch is one new ATS of our company developed by the microcomputer control technology. This series ATS is settled AM2, DZ65 circuit breaker as the executive element, and along with the mechanotronics, the new control mechanism with electromechanical double interlock, which is especially applied in the important places not allowed power off. To meet actual demand, three different operation methods are available such as automatic entry automatic reset, automatic entry non automatic reset and commutative standby.
Main features:
Three available operation methods
1. Automatic entry automatic reset
2.Automatic entry non automatic reset
3.Commutative standby
Three steady operating positions
1. The grid power supply is making, the standby power supply is
breaking.
2. The grid power supply is breaking, the standby power supply is
making.
3. The grid power supply is breaking, the standby power supply is
breaking.
Compact size, single structure, beautiful outlook, 33~630A
available, convenient operation and long operating life, 2,3,4P can
be supplied.
The transfer is drived by single motor. single structure, reliable
transfer, no noise and small wallop.
The switch is with electromechanical interlock protection, which
can ensure the two power supplies working normally, no disturbance,
The switch can be along with load automatic transfer, on urgent
situation, it can be transferred by handle.
Advantages comparative to other products:
1.The breaking capacity of the control protecting fuse is 50KA,
which increases the distribution safety.
2.Theres interlock between manual and automatic operation, this can
avoid the manual operation on the automatic operation.
3. When the executive handle of circuit breaker is broken, the
contact is felted or the load is in problem( overload, short
circuit), the ATS do not transfer, this is called the real
electromechanical interlock.
4.The driving mechanism of MCB type ATS is changed from fork type
to concave type, which solve the problem of the break of the long
handle type MCB and the non-synchronization of MCB making etc. thus
strengthen the function of fast making and breaking, and enhance
the mechanical life.
5.The wrong wire connection indication can be supplied. When the
phase wire and zero wire is connected wrong, the sound-photo device
will alarm, it ensures the reliability.
JATS and DZ65series
non-standard product Standard product
Note:
1. To the nonstandard products, the detailed requirement should be
noted. Eg. The type of fire protection signal ( constant voltage
DC24V/impulse DC 24V/ constant voltage AC220V/impulse AC 220V.
Without note, itll be considered DC24V.) the type, quantity of no
power feedback signal ( the default value is the feedback signal in
the position of No.1 group.)
2. If theres special request of the executive circuit breaker,
tripper, it should be noted.
JATS INT series:9
Standard product non-standard product
Note:
To the nonstandard products, the specific type of fire protection
signal should be noted. Without note, the default be considered
DC24V.
In compliance with standardIEC60947-6-1:1998(1.2 version)The 6th
part of low voltage switchgear and controlling equipment automatic
transfer switch.GB14048.11-2002 low voltage switchgear and
controlling equipment automatic transfer switch.
Features:
In compliance with standard
IEC60947-6-1:1998(1.2 version)
The 6th part of low voltage switchgear and controlling equipment
automatic transfer switch.
GB14048.11-2002 low voltage switchgear and controlling equipment
automatic transfer switch.
Protection grade: IP20
Application:
AC-33B(CB products) / AC-23B(PC products)
Service condition:
The altitude of installation site not higher than 2000m
Ambient temperature: -25C~55C, relative humidity < 95% at 55C.
Pollution level: III
Electrical perfomance & function
JATS automatic transfer switch decide if it should turn from one
power supply to the
other power supply according to its voltage status and operation
mode set by users. The functions depend on its controller which
consists of A type and B type. Please refer its main functions to
table 1(Next page)
Table 1 functions of controller in JATS automatic transfer switch
Note:
1) If working voltage is the same as power voltage, the common
power supply and standby power supply can supply power directly. If
not, it must use BC or equivalent isolation transformer.
2) Under the situation of handle operation, if the control circuit
of electrical manipulating device is open, automatic controlling
function will be invalid.
3) On conditions both common power supply and standby power supply
are normal, if common power supply is malfunction and automatically
transfer to standby power supply (